Air conditioning systems work hard here in Naples, FL. Therefore, Dolphin Cooling does too.
We provide AC service & maintenance from Ft Myers to Marco Island. Regular maintenance keeps your system running reliably and efficiently. Choose the plan that’s right for you.
Maintenance plans
| Feature | Tune-Up | VIP-1 | VIP-2 |
|---|---|---|---|
| Visits per year | 1 | 2 | 4 |
| Inspect A/H & condensing unit | ✓ | ✓ | ✓ |
| Filter media replacements | 2 included | 2 included | 2 included |
| Drain line cleaning | Standard | Advanced | Advanced |
| Drain line warranty | – | 30 days | 30 days |
| Issue recommendations | ✓ | ✓ | ✓ |
| Priority scheduling | — | ✓ | ✓ |
| 1-year warranty on installed parts | — | ✓ | ✓ |
| Discounted after-hours dispatch | — | ✓ | ✓ |
| FREE electronic leak search | — | ✓ | ✓ |
| FREE service call per residence | — | 1/year | 1/year |
| Discount on repairs & service | — | 15% off | 15% off |
| Indoor air quality (IAQ) discount | — | 20% off | 20% off |
Maintenance check points
| Indoor unit | Outdoor unit |
|---|---|
| Check cooling coil condition, cleanliness, corrosion, leaks, microbial growth. Clean as needed. | Check condenser coil condition, obstructions, debris, corrosion, leaks. Clean as needed. |
| Check metering device for restrictions & leaks. | Check condenser fan blades and motor. Clean as needed. |
| Check drain pan for cleanliness, leaks and microbial growth. Clean as needed. Add biocide tablets. | Check compressor amp draw. |
| Clear drain lines & test safety switches. | Check high voltage electrical connections. |
| Clean interior of cabinet as needed. | Check contractor & capacitor. Recommend replacement as needed. |
| Check UV light, clean bulb, recommend replacement if necessary. | Check and record fan motor amp draw. |
| Check blower for cleanliness, inspect motor. Clean as needed. | Check refrigerant charge. |
| Check high voltage connections, relays & capacitor. | Check and record super heat. |
| Check circuit breaker or fuse. | Check and record sub-cooling. |
| Check electric heater voltage & amp draw. | Check circuit breaker or fuse. |
| Check low voltage controls & connections. | Check refrigerant lines for damage. |
| Inspect plenums for leaks. | Check surrounding area for obstructions that could limit air flow. |
| Check static pressure to confirm proper air flow. | Check hurricane straps for corrosion or loose connections. |
| Test thermostat, reprogram as needed. | Inspect the overall condition of the unit. |